tty: stdio properties are undefined inside exec() child #2333
When the new process is created, the process.stdin is actually a PIPE and it doesn't have isTTY, isRaw and setRawMode defined. We can actually fix them like this, I think
diff --git a/src/node.js b/src/node.js
index af66b17..87121bc 100644
--- a/src/node.js+++ b/src/node.js@@ -717,6 +717,12 @@
stdin._handle.readStop();
});
+ stdin.isTTY = true;+ stdin.isRaw = false;+ stdin.setRawMode = function setRawMode(mode) {+ throw new Error('Not a Raw device');+ };+
return stdin;
});
process.stdout object is actually a Socket object, so columns and rows will not make sense in this case.
The isTTY is set in tty module's ReadStream constructor function. When the new process is created, guessHandleType calls uv_guess_handle with fd as 0 and than returns PIPE, instead of TTY. So, a net.Socket is created and returned. If uv_guess_handle returned TTY, tty.ReadStream would have been invoked, and isTTY and isRaw would be set properly.
Hmm, I don't see the process.stdin getter invoked at all when accessing these properties, so your patch doesn't seem to change anything. I'm guessing we have to check out ttywrap.
It irks me that properties that are meant to be boolean are returning undefined, but in most cases it won't matter because user code will make use of implicit Boolean(undefined) === false. Still I think a patch to initialize isTTY and isRaw to false would not hurt for the sake of correctness.
Overall, the TTY docs could certainly be improved, for example the isTTY boolean isn't properly documented, and I think a link from the process properties to the TTY docs would certainly clear up the fact that stdio streams have special properties.
Reacted by Chris Gaudreau, getsnoopy and Matthew Gamble
I took a look at the code yesterday and then realized it's not clear to me what the issue is. Is there any chance someone could sum up what the problem/requested change is here? Thanks!
The idea is to have meaningful values to the below 4 properties for Node child processes. Right now, they are undefined. A test case that manifests the issue is in the original posting above.
process.stdin.isTTY
process.stdin.isRaw
process.stdin.setRawMode
process.stdout.columns
Apparently it is a trivial change, but a bit of complexity arises due to the fact plurality of Node child processes can be created through exec, fork and spawn family functions that uses different and tunable mechanisms for stdio creation. So the fix would be to reflect on the process creation and set these values accordingly.
I don't know about stubbing .setRawMode(). No meaningful way to implement except for throwing an exception, but that breaks feature detection: if (handle.setRawMode) handle.setRawMode(true).
No meaningful value exists for .columns when the handle isn't a tty, except maybe zero. Not really an improvement.
@bnoordhuis - agreed on the points you mentioned , but did not follow the last phrase :) - you meant to say you recommend the status quo, right? Just double checking.
Activity
thefourtheye commentedon Aug 9, 2015
When the new process is created, the
process.stdinis actually a PIPE and it doesn't haveisTTY,isRawandsetRawModedefined. We can actually fix them like this, I thinkprocess.stdoutobject is actually aSocketobject, socolumnsandrowswill not make sense in this case.silverwind commentedon Aug 9, 2015
Doing this unconditionally worries me a bit. For the isTTY case, I wonder why the code path in
tty_wrap.ccthat sets it isn't triggered.thefourtheye commentedon Aug 9, 2015
The
isTTYis set inttymodule'sReadStreamconstructor function. When the new process is created,guessHandleTypecallsuv_guess_handlewithfdas0and than returnsPIPE, instead ofTTY. So, anet.Socketis created and returned. Ifuv_guess_handlereturnedTTY,tty.ReadStreamwould have been invoked, andisTTYandisRawwould be set properly.silverwind commentedon Aug 9, 2015
Hmm, I don't see the
process.stdingetter invoked at all when accessing these properties, so your patch doesn't seem to change anything. I'm guessing we have to check out ttywrap.thefourtheye commentedon Aug 9, 2015
@silverwind Actually, I tested the changes and it is working fine. Shall I submit a PR with the code in this issue as a test?
silverwind commentedon Aug 9, 2015
Go ahead, it's good to have a PR so we can run CI anyways.
thefourtheye commentedon Aug 9, 2015
@silverwind I am not making changes for the
columnsandrows, as they will beundefinedanyway.silverwind commentedon Aug 9, 2015
I'm primarily after
stdin.isTTY, but I wasn't seeing any difference, it looked as ifstartup.processStdiowas never invoked.brendanashworth commentedon Aug 10, 2015
Mmm #2160?
14 remaining items
silverwind commentedon Jul 12, 2016
It irks me that properties that are meant to be boolean are returning
undefined, but in most cases it won't matter because user code will make use of implicitBoolean(undefined) === false. Still I think a patch to initializeisTTYandisRawtofalsewould not hurt for the sake of correctness.Overall, the TTY docs could certainly be improved, for example the
isTTYboolean isn't properly documented, and I think a link from theprocessproperties to the TTY docs would certainly clear up the fact that stdio streams have special properties.kaicataldo commentedon Jun 4, 2017
Is this still an issue? Looking to contribute and it looks like both are initialized to a boolean value (though
isTTYis initialized totrue). Thanks!debugpai commentedon Jan 12, 2018
Can some of the maintainers have a look at this thread please? I was looking to pick it up too but there's no data if its still required or not
gireeshpunathil commentedon May 23, 2018
@debugpai2 - are you still interested to take this up?
kaicataldo commentedon May 23, 2018
If @debugpai2 isn't, I am! Let me see if I can take a look this week.
debugpai commentedon May 24, 2018
I am quite busy this month so won't be able to. If anyone else wants to take it up, feel free to do so.
kaicataldo commentedon May 24, 2018
I took a look at the code yesterday and then realized it's not clear to me what the issue is. Is there any chance someone could sum up what the problem/requested change is here? Thanks!
gireeshpunathil commentedon May 24, 2018
The idea is to have meaningful values to the below 4 properties for Node child processes. Right now, they are
undefined. A test case that manifests the issue is in the original posting above.Apparently it is a trivial change, but a bit of complexity arises due to the fact plurality of Node child processes can be created through
exec,forkandspawnfamily functions that uses different and tunable mechanisms forstdiocreation. So the fix would be to reflect on the process creation and set these values accordingly./cc @silverwind if I missed anything.
bnoordhuis commentedon May 25, 2018
I don't know about stubbing
.setRawMode(). No meaningful way to implement except for throwing an exception, but that breaks feature detection:if (handle.setRawMode) handle.setRawMode(true).No meaningful value exists for
.columnswhen the handle isn't a tty, except maybe zero. Not really an improvement.I think I'd leave well enough alone.
gireeshpunathil commentedon May 25, 2018
@bnoordhuis - agreed on the points you mentioned , but did not follow the last phrase :) - you meant to say you recommend the status quo, right? Just double checking.
bnoordhuis commentedon May 25, 2018
Yes, the status quo.
gireeshpunathil commentedon Jun 1, 2018
closing based on the above discussion